Corrugated Metals Products: V-Beam Roofing and Siding

V-Beam industrial roofing and siding are commonly used for industrial warehouses and buildings requiring cryogenic/temperature control.

For example, V-Beam wall panels are frequently used in power plant lagging, and V-Beam roofing and siding are used in pulp and paper mills.
Please select one of the links below to view more details about our V-Beam roofing and siding. Or you can contact a Corrugated Metals representative at 1-800-621-5617.

v-beam

V-BEAM














The finished width is 37-1/2″ with a 34-1/8″ wide cover. This is also available for plain galvanized.

Download our full color chart to see what options are available. Click here to download the PDF.

Load Table

PANEL

V-BEAM

LIVE LOAD

20 PSF

30 PSF

40 PSF

50 PSF

SPAN

ROOF

WALL

ROOF

WALL

ROOF

WALL

ROOF

WALL

20
210 lbs/sq

1

9′-6″

9′-10″

8′-5″

8′-7″

7′-8″

7′-10″

7′-2″

7′-2″

2

11-11

13-3

9-11

11-7

8-8

10-3

7-9

9-2

3

11-9

12-2

10-5

10-8

9-6

9-8

8-9

9-0

22
179 lbs/sq

1

9-0

9-3

7-11

8-1

7-3

7-4

6-9

6-10

2

11-1

12-5

9-2

10-10

8-0

9-5

7-2

8-5

3

11-2

11-6

9-10

10-0

8-11

9-1

8-0

8-5

24
146 lbs/sq

1

8-5

8-8

7-5

7-6

6-9

6-10

6-4

6-4

2

9-11

11-7

8-2

9-8

7-2

8-5

6-5

7-6

3

10-5

10-8

9-2

9-4

8-0

8-5

7-2

7-10

032
57 lbs/sq

1

9-2

9-3

8-0

8-1

7-1

7-4

6-4

6-10

2

9-8

11-4

7-11

9-3

6-10

8-0

6-2

7-2

3

10-9

11-5

8-10

10-0

7-8

8-11

6-11

8-0

040
72 lbs/sq

1

9-10

9-11

8-7

8-8

7-10

7-11

7-1

7-4

2

10-8

12-7

8-9

10-3

7-8

8-11

6-10

7-11

3

11-11

12-3

9-10

10-9

8-6

9-9

7-8

8-11

Notes – Steel

  1. Roof loads are for positive loads only and are in addition to weight
    of panel.
  2. Other gauges of steel and aluminum are available upon inquiry.
  3. Maximum allowable stress for Grade A (F) = 20,000 PSI for roofs
    and 26,667 PSI for walls where wind is the only load.
  4. Loads and spans for carbon steel are based on the AISI Cold Formed
    Steel Design Manual.
  5. Other gauges of steel may be available upon inquiry.

Notes – Aluminum

  1. Roof loads are for positive loads only and are in addition to weight
    of panel.
  2. Other gauges of steel and aluminum are available upon inquiry.
  3. Maximum allowable stress (FC) = 15,000 PSI, (FT) = 17,000 PSI for
    roof and side wall. Stresses have been increased 1/3 for wind loading.
  4. Loads and spans for aluminum are based on Aluminum Formed Sheet
    Building Sheathing Design Guide.

If you would like more information about our v-beam industrial roofing
and siding or any of our corrugated metal products, please call us at
1-800-621-5617, fill out our contact form
or email us at info@corrugated-metals.com.