Corrugated Metals Products: Box Beam Roofing and Siding

Box Beam industrial roofing and siding are commonly used for industrial warehouses and buildings requiring cryogenic/temperature control. Box Beam is stronger than our 4″ Box Rib.

To view more details about our Box Beam roofing and siding products, you can contact a Corrugated Metals representative at 1-800-621-5617.

box-beam

BOX-BEAM














Note: Other widths available upon request.

Download our full color chart to see what options are available. Click here to download the PDF.

Load Table

PANEL

BOX BEAM

LIVE LOAD

20 PSF

30 PSF

40 PSF

50 PSF

SPAN

ROOF

WALL

ROOF

WALL

ROOF

WALL

ROOF

WALL

18
301 lbs/sq

1

10′-9″

11′-3″

9′-7″

9′-10″

8′-9″

8′-11″

8′-2″

8′-4″

2

14-5

15-2

12-10

13-3

11-3

12-0

10-1

11-2

3

13-4

13-11

11-9

12-2

10-10

11-1

10-1

10-3

20
233 lbs/sq

1

9-11

10-3

8-9

8-11

8-0

8-1

7-5

7-7

2

12-11

13-9

10-9

12-0

9-5

10-11

8-5

10-0

3

12-2

12-8

10-9

11-1

9-10

10-0

9-2

9-4

22
196 lbs/sq

1

9-3

9-6

8-2

8-4

7-6

7-6

6-11

7-0

2

11-6

12-9

9-7

11-2

8-4

9-10

7-6

8-10

3

11-5

11-9

10-0

10-3

9-2

9-4

8-4

8-8

24
161 lbs/sq

1

8-6

8-8

7-6

7-7

6-10

6-11

6-4

6-5

2

10-0

11-8

8-3

9-9

7-2

8-5

6-5

7-7

3

10-5

10-9

9-2

9-4

8-0

8-6

7-2

7-11

032
65 lbs/sq

1

8-0

9-0

6-7

7-5

5-9

6-5

5-1

5-9

2

7-9

9-0

6-4

7-5

5-6

6-5

4-11

5-9

3

8-7

10-1

7-1

8-3

6-2

7-2

5-6

6-5

040
81 lbs/sq

1

9-11

10-4

8-1

9-0

7-1

7-11

6-4

7-1

2

9-6

11-2

7-10

9-2

6-10

7-11

6-1

7-1

3

10-8

12-6

8-9

10-3

7-7

8-10

6-10

7-11

Notes – Steel

  1. Roof loads are for positive loads only and are in addition to weight
    of panel.
  2. Other gauges of steel and aluminum are available upon inquiry.
  3. Maximum allowable stress for Grade A (F) = 20,000 PSI for roofs
    and 26,667 PSI for walls where wind is the only load.
  4. Loads and spans for carbon steel are based on the AISI Cold Formed
    Steel Design Manual.
  5. Other gauges of steel may be available upon inquiry.

Notes – Aluminum

  1. Roof loads are for positive loads only and are in addition to weight
    of panel.
  2. Other gauges of steel and aluminum are available upon inquiry.
  3. Maximum allowable stress (FC) = 15,000 PSI, (FT) = 17,000 PSI for
    roof and side wall. Stresses have been increased 1/3 for wind loading.
  4. Loads and spans for aluminum are based on Aluminum Formed Sheet
    Building Sheathing Design Guide.

If you would like more information about our box beam products or any
other of our corrugated metal products, please call us at 1-800-621-5617,
fill out our contact form or email us at
info@corrugated-metals.com.